A check valve, also called a non-return valve, allows water to flow in one direction only and automatically blocks reverse flow. It protects pumps, filters, pressure regulators, fertilizer injectors, and the water source from backflow, back-siphonage, reverse pressure, and possible contamination. It is commonly installed after pumps, near fertigation units, near filter-regulator assemblies, or on drip irrigation mainlines.

Coming soon This material is currently not in stock. Please visit us again later, or send an inquiry if you would like to be notified when it becomes available.

Product Description

A check valve, also called a non-return valve, is a protective valve that allows water to flow in one direction only and automatically prevents water from flowing backward. It is an important component in drip irrigation, sprinkler irrigation, pump systems, fertigation units, filtration units, and mainline water distribution systems.

In normal operation, water flows in the correct direction from the inlet to the outlet. The pressure of the moving water pushes the internal disc, poppet, flap, or spring-loaded mechanism open, allowing water to pass through the valve. When the pump stops or when reverse pressure occurs, the valve closes automatically and blocks backflow.

This is important because reverse flow can damage pumps, filters, pressure regulators, fertigation units, and upstream components. In irrigation systems using fertilizer injectors or Venturi injectors, a check valve helps prevent fertilizer solution from flowing backward into the clean water source. It also helps reduce back-siphonage, line drainage, reverse pressure movement, and possible contamination of the water supply.

A check valve is commonly installed after a pump, near a fertilizer injector, before or after a filter-regulator assembly, or on the mainline of a drip irrigation system. Its main purpose is not to control irrigation timing, but to protect the system by ensuring that water moves only in the intended direction.

Availability, Delivery and Support

Stock Status coming_soon

For special delivery, bulk purchase, technical support, or supplier confirmation, visitors can send an inquiry before purchase.

Ask About Availability

Customer Reviews

Customer Reviews

Reviews are published after admin approval.

0.0 / 5
☆☆☆☆☆
0 approved reviews
Direct link

Technical Material Information

Manufacturer / Producer
Produced by irrigation valve, pipe-fitting, water-control, and pump-system manufacturers. Common producers include irrigation and hydraulic equipment companies that manufacture plastic, brass, PVC, PP, and metal non-return valves. The exact producer depends on valve size, material, pressure rating, connection type, and system application.
Manufacturer Note
Best Used With:
Pump system, drip irrigation mainline, sprinkler system, filter, pressure regulator, fertigation unit, Venturi injector, fertilizer tank, pressure gauge, and irrigation control assembly.

Practical Installation Note:
Install the valve in the correct direction. The arrow on the valve body must match the direction of normal water flow. If it is installed backward, water may not pass correctly. Ensure fittings are tight, pipe support is adequate, and the valve is accessible for inspection and maintenance.
Material
Produced by irrigation valve, pipe-fitting, water-control, and pump-system manufacturers. Common producers include irrigation and hydraulic equipment companies that manufacture plastic, brass, PVC, PP, and metal non-return valves. The exact producer depends on valve size, material, pressure rating, connection type, and system application.
Pipe / Tape Diameter
Common sizes include 16 mm, 20 mm, 25 mm, 32 mm, 40 mm, 50 mm, 63 mm, 75 mm, and larger sizes for mainline systems. The correct size should match pipe diameter, flow rate, and pressure requirements.
Connection Type
Compression, threaded BSP / NPT, union, socket, flange, or barbed connection depending on valve size and irrigation system design.
Working Pressure
Typical working pressure may range from low-pressure irrigation systems up to PN10 or higher, depending on the valve model and manufacturer. The selected valve must match the operating pressure of the system.
Flow Rate
Flow rate depends on valve size, pipe diameter, pressure, and manufacturer specification. The valve should be selected so that it allows the required system flow with minimum pressure loss.
Application
Main Use:
Used to prevent backflow, protect pumps, protect filters, stop fertilizer solution from returning to the water source, maintain pump prime, reduce back-siphonage, and improve irrigation system reliability.

Key Benefits:

Allows one-way water flow only
Prevents reverse flow and back-siphonage
Protects pumps from reverse pressure
Protects filters, regulators, and valves
Helps stop fertilizer or chemical solution from returning to the water source
Reduces system damage when the pump stops
Improves irrigation system safety and reliability
Works automatically without manual operation

How It Works:
When water flows forward, the internal disc, poppet, or spring mechanism opens and allows water to pass. When water tries to flow backward, reverse pressure pushes the disc or poppet against the sealing seat. The valve closes and blocks the reverse flow.